{"id":623,"date":"2026-09-28T08:00:00","date_gmt":"2026-09-28T00:00:00","guid":{"rendered":"https:\/\/anchor-aerogel.com\/?p=623"},"modified":"2026-09-25T11:35:37","modified_gmt":"2026-09-25T03:35:37","slug":"anwendung-von-aerogel-isolierdecken-auf-niedertemperatur-rohrleitungen","status":"publish","type":"post","link":"https:\/\/anchor-aerogel.com\/de\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/","title":{"rendered":"Aerogel-Matte f\u00fcr kryogene Rohrleitungen: Kondensation und CUI beenden"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"623\" class=\"elementor elementor-623\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d4ae830 e-flex e-con-boxed e-con e-parent\" data-id=\"d4ae830\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-250ea0a elementor-widget elementor-widget-heading\" data-id=\"250ea0a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Anwendung von Aerogel-D\u00e4mmdecken an Niedertemperatur-Rohrleitungen<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2e297a3 e-flex e-con-boxed e-con e-parent\" data-id=\"2e297a3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-84f7f3d elementor-widget elementor-widget-text-editor\" data-id=\"84f7f3d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Aerogel-D\u00e4mmmatten k\u00f6nnen bei Temperaturen bis zu -200 \u00b0C optimale K\u00fchlwirkung und energiesparenden wirtschaftlichen Nutzen bieten. In der petrochemischen Industrie werden Aerogel-D\u00e4mmmatten h\u00e4ufig in Niedertemperatur-Rohrleitungen eingesetzt (im Allgemeinen sind damit Rohrleitungen mit Betriebstemperaturen unter -20 \u00b0C gemeint).<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9b2210b e-flex e-con-boxed e-con e-parent\" data-id=\"9b2210b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-6921b8e e-con-full e-flex e-con e-child\" data-id=\"6921b8e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-66355fc elementor-widget elementor-widget-text-editor\" data-id=\"66355fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Ma\u00dfnahme, die Au\u00dfenseite von Niedertemperatur-Rohrleitungen mit D\u00e4mmmaterialien zu umh\u00fcllen, um die W\u00e4rmeleitung von au\u00dfen in die Rohrleitung zu reduzieren und die Oberfl\u00e4chentemperatur \u00fcber dem Taupunkt zu halten, wodurch Kondensation an der Au\u00dfenfl\u00e4che verhindert wird, wird als K\u00e4lted\u00e4mmung bezeichnet. Das auf der Au\u00dfenseite der Rohrleitung angebrachte D\u00e4mmmaterial wird \u00fcblicherweise als K\u00e4lted\u00e4mmmaterial bezeichnet.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb9d830 elementor-widget elementor-widget-text-editor\" data-id=\"fb9d830\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Auswahl geeigneter K\u00e4lted\u00e4mmmaterialien ist wesentlich f\u00fcr die Verbesserung der K\u00e4lted\u00e4mmungseffizienz, die Sicherung der Qualit\u00e4t des Mediums am Austritt und die F\u00f6rderung von Energieeinsparung und Umweltschutz.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-104ae9c e-con-full e-flex e-con e-child\" data-id=\"104ae9c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-138b5ef elementor-widget elementor-widget-image\" data-id=\"138b5ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"690\" height=\"517\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg\" class=\"attachment-large size-large wp-image-624\" alt=\"Anwendung von Aerogel-D\u00e4mmdecken an Niedertemperatur-Rohrleitungen\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg 690w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1-300x225.jpg 300w\" sizes=\"(max-width: 690px) 100vw, 690px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bd36ffb e-flex e-con-boxed e-con e-parent\" data-id=\"bd36ffb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8d6d3c1 elementor-widget elementor-widget-heading\" data-id=\"8d6d3c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Traditionelle K\u00e4lted\u00e4mmmaterialien<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-521bd5c e-flex e-con-boxed e-con e-parent\" data-id=\"521bd5c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-c4b9443 e-con-full e-flex e-con e-child\" data-id=\"c4b9443\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8e04aae elementor-widget elementor-widget-image\" data-id=\"8e04aae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"459\" height=\"272\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/002-1-1.jpg\" class=\"attachment-large size-large wp-image-633\" alt=\"Anwendung von Aerogel-D\u00e4mmdecken an Niedertemperatur-Rohrleitungen\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/002-1-1.jpg 459w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/002-1-1-300x178.jpg 300w\" sizes=\"(max-width: 459px) 100vw, 459px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-07483f2 e-con-full e-flex e-con e-child\" data-id=\"07483f2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3c14693 elementor-widget elementor-widget-text-editor\" data-id=\"3c14693\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Derzeit umfassen die \u00fcblicherweise verwendeten K\u00e4lted\u00e4mmmaterialien haupts\u00e4chlich Polyurethan, Gummi-Kunststoff, Steinwolle usw. Im Vergleich zu den fr\u00fcher verwendeten Perlit-Materialien wurden diese Materialien hinsichtlich Leistung und Konstruktion erheblich verbessert. Die Einf\u00fchrung von Aerogel-K\u00e4lted\u00e4mmmaterialien stellt jedoch eine qualitative Ver\u00e4nderung f\u00fcr das bestehende kryogene K\u00e4lted\u00e4mmsystem dar.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0bc4de5 e-flex e-con-boxed e-con e-parent\" data-id=\"0bc4de5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c4ce887 elementor-widget elementor-widget-heading\" data-id=\"c4ce887\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Aktueller Stand traditioneller D\u00e4mmmaterialien:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-58e6939 e-flex e-con-boxed e-con e-parent\" data-id=\"58e6939\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-00671f6 e-con-full e-flex e-con e-child\" data-id=\"00671f6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-600541f elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"600541f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Traditionelle D\u00e4mmmaterialien erfahren einen schnellen R\u00fcckgang der D\u00e4mmleistung, was zu hohen Instandhaltungskosten f\u00fchrt.<\/li><li>Traditionelle D\u00e4mmmaterialien haben schlechte K\u00e4lted\u00e4mmwirkung, was zu erheblichen Verlusten der K\u00fchlleistung f\u00fchrt.<\/li><li>Traditionelle D\u00e4mmmaterialien haben eine gro\u00dfe Umh\u00fcllungsdicke, was viele Unannehmlichkeiten f\u00fcr die Planung dicht angeordneter Rohrleitungen mit sich bringt. Rohrleitungen sind aufgrund der schlechten K\u00e4lted\u00e4mmwirkung anf\u00e4llig f\u00fcr Korrosion durch Kondenswasser (CUI).<\/li><li>K\u00e4lted\u00e4mmschichten verlieren leicht ihre Wirksamkeit durch \u00fcberm\u00e4\u00dfige Kondensation. Organische Materialien haben ausgezeichnete wasserabweisende Eigenschaften, k\u00f6nnen jedoch die Brandschutzanforderungen nicht erf\u00fcllen.<\/li><\/ul>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d5591b1 e-con-full e-flex e-con e-child\" data-id=\"d5591b1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2e41d0e elementor-widget elementor-widget-image\" data-id=\"2e41d0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"757\" height=\"449\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/003-2.jpg\" class=\"attachment-large size-large wp-image-640\" alt=\"Anwendung von Aerogel-D\u00e4mmdecken an Niedertemperatur-Rohrleitungen\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/003-2.jpg 757w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/003-2-300x178.jpg 300w\" sizes=\"(max-width: 757px) 100vw, 757px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4d76beb e-flex e-con-boxed e-con e-parent\" data-id=\"4d76beb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3fed082 elementor-widget elementor-widget-heading\" data-id=\"3fed082\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Anchor Tech Aerogel-D\u00e4mmmatte<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1f7db90 e-flex e-con-boxed e-con e-parent\" data-id=\"1f7db90\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-bbaffe8 e-con-full e-flex e-con e-child\" data-id=\"bbaffe8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-32f54b9 elementor-widget elementor-widget-text-editor\" data-id=\"32f54b9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Anchor Tech Aerogel-D\u00e4mmmatte ist eine flexible K\u00fchld\u00e4mmmatte, die durch fortschrittliche Nanokomposit-Technologie hergestellt wird und Nano-Silica-Aerogel mit anorganischen Materialien kombiniert.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7d3990e e-flex e-con-boxed e-con e-parent\" data-id=\"7d3990e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a534c0e elementor-widget elementor-widget-heading\" data-id=\"a534c0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Produktvorteile:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-48513b9 e-flex e-con-boxed e-con e-parent\" data-id=\"48513b9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-71b9d91 e-con-full e-flex e-con e-child\" data-id=\"71b9d91\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9a131b7 elementor-widget elementor-widget-image\" data-id=\"9a131b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"750\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/004.webp\" class=\"attachment-large size-large wp-image-645\" alt=\"Anwendung von Aerogel-D\u00e4mmdecken an Niedertemperatur-Rohrleitungen\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/004.webp 750w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/004-300x300.webp 300w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/004-150x150.webp 150w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3429421 e-con-full e-flex e-con e-child\" data-id=\"3429421\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b12fbb0 elementor-widget elementor-widget-image\" data-id=\"b12fbb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"629\" height=\"329\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/003-1.jpg\" class=\"attachment-large size-large wp-image-489\" alt=\"\u00dcber Aerogele \u2013 das sollten Sie wissen\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/003-1.jpg 629w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/003-1-300x157.jpg 300w\" sizes=\"(max-width: 629px) 100vw, 629px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c52056f e-flex e-con-boxed e-con e-parent\" data-id=\"c52056f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4658ea5 e-con-full e-flex e-con e-child\" data-id=\"4658ea5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6060fbc elementor-widget elementor-widget-text-editor\" data-id=\"6060fbc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>1. Sie weist eine hervorragende K\u00fchld\u00e4mmleistung mit extrem niedriger W\u00e4rmeleitf\u00e4higkeit auf und bietet optimale K\u00fchleffekte sowie energiesparenden wirtschaftlichen Nutzen selbst bei Temperaturen von nur -200\u00b0C.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea392dc elementor-widget elementor-widget-text-editor\" data-id=\"ea392dc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>2. Die Aerogel-D\u00e4mmmatte hat \u00fcberlegene Feuerbest\u00e4ndigkeit und hydrophobe Eigenschaften, hemmt effektiv das Eindringen von Wasser in die Oberfl\u00e4che der Metallrohrleitung, verhindert Rohrleitungskorrosion (CUI) und vermeidet eine Verringerung der K\u00fchld\u00e4mmeffizienz durch Wassereindringung.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c0bef68 e-con-full e-flex e-con e-child\" data-id=\"c0bef68\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9d6c97d elementor-widget elementor-widget-image\" data-id=\"9d6c97d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"226\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/008.gif\" class=\"attachment-large size-large wp-image-652\" alt=\"Anwendung von Aerogel-D\u00e4mmdecken an Niedertemperatur-Rohrleitungen\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e6b1705 e-flex e-con-boxed e-con e-parent\" data-id=\"e6b1705\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-e8c3611 e-con-full e-flex e-con e-child\" data-id=\"e8c3611\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-90701f0 elementor-widget elementor-widget-text-editor\" data-id=\"90701f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>3. Die Aerogel-D\u00e4mmmatte ist 75% d\u00fcnner in der Dicke im Vergleich zu \u00e4hnlichen Produkten, was eine schnellere und einfachere Installation dieses K\u00fchld\u00e4mmmaterials erm\u00f6glicht und sowohl Zeit als auch Kosten spart.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ddc959 elementor-widget elementor-widget-text-editor\" data-id=\"1ddc959\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>4. Das Material ist leicht zu schneiden, was eine bequeme Verarbeitung erm\u00f6glicht. Es ist sicher, umweltfreundlich, ungiftig und hat eine lange Lebensdauer.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5480d8b e-con-full e-flex e-con e-child\" data-id=\"5480d8b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-acf2c66 elementor-widget elementor-widget-image\" data-id=\"acf2c66\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"663\" height=\"605\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009-1-1.jpg\" class=\"attachment-large size-large wp-image-666\" alt=\"Anwendung von Aerogel-D\u00e4mmdecken an Niedertemperatur-Rohrleitungen\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009-1-1.jpg 663w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009-1-1-300x274.jpg 300w\" sizes=\"(max-width: 663px) 100vw, 663px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-eaadc21 e-flex e-con-boxed e-con e-parent\" data-id=\"eaadc21\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eb7a987 elementor-widget elementor-widget-heading\" data-id=\"eb7a987\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Anwendungsszenarien:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-48638d3 e-flex e-con-boxed e-con e-parent\" data-id=\"48638d3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-87560c4 e-con-full e-flex e-con e-child\" data-id=\"87560c4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-204e79f elementor-widget elementor-widget-text-editor\" data-id=\"204e79f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Anchor Tech Aerogel-D\u00e4mmmatte kann K\u00e4lteverluste und Verdampfungsgasverluste (BOG) erheblich reduzieren. Sie eignet sich f\u00fcr tiefkryogene Rohrleitungsanlagen, mittel- und niedrigtemperierte Rohrleitungen, Kaltluftventilatoren\/Abgasrohre usw., wie LNG-Lagerung und -Transport, Fl\u00fcssigstickstoff- und Fl\u00fcssigsauerstoff-Lageranlagen oder Transportrohre usw.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b305aef e-con-full e-flex e-con e-child\" data-id=\"b305aef\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09b29e1 elementor-widget elementor-widget-image\" data-id=\"09b29e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"571\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/010-2.jpg\" class=\"attachment-large size-large wp-image-659\" alt=\"Anwendung von Aerogel-D\u00e4mmdecken an Niedertemperatur-Rohrleitungen\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/010-2.jpg 826w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/010-2-300x214.jpg 300w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/010-2-768x549.jpg 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-abb73a0 e-flex e-con-boxed e-con e-parent\" data-id=\"abb73a0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b56f066 elementor-widget elementor-widget-heading\" data-id=\"b56f066\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Anwendungsfall:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4c49a1a e-flex e-con-boxed e-con e-parent\" data-id=\"4c49a1a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-c0c9e87 e-con-full e-flex e-con e-child\" data-id=\"c0c9e87\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e9810cc elementor-widget elementor-widget-image\" data-id=\"e9810cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"447\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/012-2.jpg\" class=\"attachment-large size-large wp-image-683\" alt=\"Anwendung von Aerogel-D\u00e4mmdecken an Niedertemperatur-Rohrleitungen\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/012-2.jpg 944w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/012-2-300x167.jpg 300w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/012-2-768x429.jpg 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cc69268 e-con-full e-flex e-con e-child\" data-id=\"cc69268\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d082ec8 elementor-widget elementor-widget-text-editor\" data-id=\"d082ec8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Es gab zwei DN100 Kaltwasserrohre mit unwirksamer Isolierung und Leckage entlang des Durchgangs zur Ecke nahe dem A-Ende-Kontrollraum der Tianhe-Passagierstation der Linie 3 der Guangzhou Metro. Die Gesamtl\u00e4nge betr\u00e4gt etwa 40 Meter. Wir haben sie mit der Aerogel-D\u00e4mmmatte ersetzt und saniert, um das Leckageproblem zu l\u00f6sen und die Betriebssicherheit zu gew\u00e4hrleisten.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-51a7ab6 e-flex e-con-boxed e-con e-parent\" data-id=\"51a7ab6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-5f82351 e-con-full e-flex e-con e-child\" data-id=\"5f82351\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3ff0d05 elementor-widget elementor-widget-text-editor\" data-id=\"3ff0d05\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Hochwertige K\u00e4lteisolationsmaterialien reduzieren nicht nur den Energieverbrauch und minimieren den Verlust an K\u00fchlleistung, sondern bieten auch eine Garantie f\u00fcr sichere Produktion und bessere Ertr\u00e4ge f\u00fcr Unternehmen. Die Aerogel-Isolierdecke von Anchor Tech ist mit ihrer hervorragenden K\u00e4lteisolationsleistung, Flammbest\u00e4ndigkeit, Hydrophobie, einfachen Zuschneidbarkeit und langen Lebensdauer die ideale Wahl f\u00fcr Kunden im Bereich der tiefen Kryotechnik, die bessere K\u00e4lteisolationsergebnisse und einen niedrigeren Energieverbrauch anstreben.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-009a9a1 e-con-full e-flex e-con e-child\" data-id=\"009a9a1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9a18244 elementor-widget elementor-widget-image\" data-id=\"9a18244\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"492\" height=\"433\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/011-1.jpg\" class=\"attachment-large size-large wp-image-679\" alt=\"Anwendung von Aerogel-D\u00e4mmdecken an Niedertemperatur-Rohrleitungen\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/011-1.jpg 492w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/011-1-300x264.jpg 300w\" sizes=\"(max-width: 492px) 100vw, 492px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-09bd832 e-flex e-con-boxed e-con e-parent\" data-id=\"09bd832\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9702122 elementor-widget elementor-widget-html\" data-id=\"9702122\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2>Verwandte Aerogel-Produkte<\/h2><ul>\n<li><a href=\"https:\/\/anchor-aerogel.com\/de\/haustier-kryo-aerogel-decke\/\">AG20 PET Kryo-Aerogel-Decke<\/a><\/li>\n<li><a href=\"https:\/\/anchor-aerogel.com\/de\/flexible-aerogel-decke\/\">AG65 Flexibler Aerogel-Isolierdecke<\/a><\/li>\n<li><a href=\"https:\/\/anchor-aerogel.com\/de\/keramikfaser-aerogel-decke\/\">AG80 Keramikfaser-Aerogel-Decke<\/a><\/li>\n<\/ul>\n<p><a href=\"https:\/\/anchor-aerogel.com\/de\/kontakt\/\">Angebot f\u00fcr diese Produkte anfordern<\/a><\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7d07bed e-con-boxed e-flex e-con e-parent\" data-id=\"7d07bed\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2080298 elementor-widget elementor-widget-heading\" data-id=\"2080298\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Aerogel-Rohrisolierung: Auswahl der Qualit\u00e4t<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c0e022 elementor-widget elementor-widget-text-editor\" data-id=\"2c0e022\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00fcr die Aerogel-Rohrisolierung sollte die Qualit\u00e4t auf die Leitungstemperatur abgestimmt werden: kryogene PET-Matten unter minus 40 \u00b0C, flexible Matten f\u00fcr den allgemeinen Einsatz und Keramikfaser-Aerogel-Qualit\u00e4ten \u00fcber 650 \u00b0C.<\/p><!--kw-2026-09-25-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-14437ca e-con-boxed e-flex e-con e-parent\" data-id=\"14437ca\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5e7f6f1 elementor-widget elementor-widget-heading\" data-id=\"5e7f6f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">So installieren Sie Aerogelmatten auf Rohren<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1c96bd elementor-widget elementor-widget-text-editor\" data-id=\"d1c96bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Um Aerogelmatten auf Rohren zu installieren, wickeln Sie die flexible Matte eng anliegend, sichern Sie sie mit B\u00e4ndern oder Draht und f\u00fcgen Sie dann eine Dampfsperre und einen Witterungsschutzmantel hinzu. Eine korrekte Dampfsperre ist das, was Korrosion unter der Isolierung \u00fcber die Nutzungsdauer verhindert. Diese kurze Installationsanleitung gilt f\u00fcr die meisten Rohrleitungen.<\/p><!--kw-2026-09-25-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Aerogel-D\u00e4mmdecke f\u00fcr Niedertemperatur-Rohrleitungen. Vergleichen Sie Aerogel mit herk\u00f6mmlichen K\u00e4lteisolationsmaterialien und sehen Sie Leistungsdaten.<\/p>","protected":false},"author":1,"featured_media":624,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9],"tags":[],"class_list":["post-623","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI - Anchor Aerogel<\/title>\n<meta name=\"description\" content=\"Cold insulation must keep the pipe surface above the dew point and stay dry. Aerogel&#039;s hydrophobicity and thin profile make it ideal for \u221220 \u00b0C to \u2212200 \u00b0C lines. \u2014 Anchor Technology Co., Ltd.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/anchor-aerogel.com\/de\/anwendung-von-aerogel-isolierdecken-auf-niedertemperatur-rohrleitungen\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI - Anchor Aerogel\" \/>\n<meta property=\"og:description\" content=\"Cold insulation must keep the pipe surface above the dew point and stay dry. Aerogel&#039;s hydrophobicity and thin profile make it ideal for \u221220 \u00b0C to \u2212200 \u00b0C lines. \u2014 Anchor Technology Co., Ltd.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/anchor-aerogel.com\/de\/anwendung-von-aerogel-isolierdecken-auf-niedertemperatur-rohrleitungen\/\" \/>\n<meta property=\"og:site_name\" content=\"Anchor Aerogel\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-28T00:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"690\" \/>\n\t<meta property=\"og:image:height\" content=\"517\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Anchor Tech Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Anchor Tech Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"2\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/\"},\"author\":{\"name\":\"Anchor Tech Team\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#\\\/schema\\\/person\\\/1fb2a61c6b00b9a4e340d577998a9daf\"},\"headline\":\"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI\",\"datePublished\":\"2026-09-28T00:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/\"},\"wordCount\":394,\"publisher\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/001-1.jpg\",\"articleSection\":[\"Application\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/\",\"name\":\"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI - Anchor Aerogel\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/001-1.jpg\",\"datePublished\":\"2026-09-28T00:00:00+00:00\",\"description\":\"Cold insulation must keep the pipe surface above the dew point and stay dry. Aerogel's hydrophobicity and thin profile make it ideal for \u221220 \u00b0C to \u2212200 \u00b0C lines. \u2014 Anchor Technology Co., Ltd.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#primaryimage\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/001-1.jpg\",\"contentUrl\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/001-1.jpg\",\"width\":690,\"height\":517,\"caption\":\"Application of Aerogel Insulation Blanket on Low-Temperature Pipelines\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/anchor-aerogel.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#website\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/\",\"name\":\"Anchor Aerogel\",\"description\":\"Advanced aerogel thermal insulation materials and blankets for extreme environments.\",\"publisher\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/anchor-aerogel.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#organization\",\"name\":\"Anchor Aerogel\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/wechat-image-logo.jpg\",\"contentUrl\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/wechat-image-logo.jpg\",\"width\":837,\"height\":405,\"caption\":\"Anchor Aerogel\"},\"image\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#\\\/schema\\\/person\\\/1fb2a61c6b00b9a4e340d577998a9daf\",\"name\":\"Anchor Tech Team\",\"sameAs\":[\"https:\\\/\\\/anchor-aerogel.com\"],\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/de\\\/author\\\/164868441qq-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Aerogel-Decke f\u00fcr kryogene Rohrleitungen: Kondensation und CUI beenden \u2013 Anchor Aerogel","description":"Kaltisolierung muss die Rohroberfl\u00e4che \u00fcber dem Taupunkt halten und trocken bleiben. Die Hydrophobie und das d\u00fcnne Profil von Aerogel machen es ideal f\u00fcr Leitungen von \u221220 \u00b0C bis \u2212200 \u00b0C. \u2014 Anchor Technology Co., Ltd.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/anchor-aerogel.com\/de\/anwendung-von-aerogel-isolierdecken-auf-niedertemperatur-rohrleitungen\/","og_locale":"de_DE","og_type":"article","og_title":"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI - Anchor Aerogel","og_description":"Cold insulation must keep the pipe surface above the dew point and stay dry. Aerogel's hydrophobicity and thin profile make it ideal for \u221220 \u00b0C to \u2212200 \u00b0C lines. \u2014 Anchor Technology Co., Ltd.","og_url":"https:\/\/anchor-aerogel.com\/de\/anwendung-von-aerogel-isolierdecken-auf-niedertemperatur-rohrleitungen\/","og_site_name":"Anchor Aerogel","article_published_time":"2026-09-28T00:00:00+00:00","og_image":[{"width":690,"height":517,"url":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg","type":"image\/jpeg"}],"author":"Anchor Tech Team","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"Anchor Tech Team","Gesch\u00e4tzte Lesezeit":"2\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#article","isPartOf":{"@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/"},"author":{"name":"Anchor Tech Team","@id":"https:\/\/anchor-aerogel.com\/#\/schema\/person\/1fb2a61c6b00b9a4e340d577998a9daf"},"headline":"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI","datePublished":"2026-09-28T00:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/"},"wordCount":394,"publisher":{"@id":"https:\/\/anchor-aerogel.com\/#organization"},"image":{"@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#primaryimage"},"thumbnailUrl":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg","articleSection":["Application"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/","url":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/","name":"Aerogel-Decke f\u00fcr kryogene Rohrleitungen: Kondensation und CUI beenden \u2013 Anchor Aerogel","isPartOf":{"@id":"https:\/\/anchor-aerogel.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#primaryimage"},"image":{"@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#primaryimage"},"thumbnailUrl":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg","datePublished":"2026-09-28T00:00:00+00:00","description":"Kaltisolierung muss die Rohroberfl\u00e4che \u00fcber dem Taupunkt halten und trocken bleiben. Die Hydrophobie und das d\u00fcnne Profil von Aerogel machen es ideal f\u00fcr Leitungen von \u221220 \u00b0C bis \u2212200 \u00b0C. \u2014 Anchor Technology Co., Ltd.","breadcrumb":{"@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#primaryimage","url":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg","contentUrl":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg","width":690,"height":517,"caption":"Application of Aerogel Insulation Blanket on Low-Temperature Pipelines"},{"@type":"BreadcrumbList","@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/anchor-aerogel.com\/"},{"@type":"ListItem","position":2,"name":"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI"}]},{"@type":"WebSite","@id":"https:\/\/anchor-aerogel.com\/#website","url":"https:\/\/anchor-aerogel.com\/","name":"Anker-Aerogel","description":"Fortschrittliche Aerogel-W\u00e4rmed\u00e4mmstoffe und -decken f\u00fcr extreme Umgebungen.","publisher":{"@id":"https:\/\/anchor-aerogel.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/anchor-aerogel.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/anchor-aerogel.com\/#organization","name":"Anker-Aerogel","url":"https:\/\/anchor-aerogel.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/anchor-aerogel.com\/#\/schema\/logo\/image\/","url":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/07\/wechat-image-logo.jpg","contentUrl":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/07\/wechat-image-logo.jpg","width":837,"height":405,"caption":"Anchor Aerogel"},"image":{"@id":"https:\/\/anchor-aerogel.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/anchor-aerogel.com\/#\/schema\/person\/1fb2a61c6b00b9a4e340d577998a9daf","name":"Anchor Tech Team","sameAs":["https:\/\/anchor-aerogel.com"],"url":"https:\/\/anchor-aerogel.com\/de\/author\/164868441qq-com\/"}]}},"_links":{"self":[{"href":"https:\/\/anchor-aerogel.com\/de\/wp-json\/wp\/v2\/posts\/623","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/anchor-aerogel.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/anchor-aerogel.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/anchor-aerogel.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/anchor-aerogel.com\/de\/wp-json\/wp\/v2\/comments?post=623"}],"version-history":[{"count":1,"href":"https:\/\/anchor-aerogel.com\/de\/wp-json\/wp\/v2\/posts\/623\/revisions"}],"predecessor-version":[{"id":4320,"href":"https:\/\/anchor-aerogel.com\/de\/wp-json\/wp\/v2\/posts\/623\/revisions\/4320"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/anchor-aerogel.com\/de\/wp-json\/wp\/v2\/media\/624"}],"wp:attachment":[{"href":"https:\/\/anchor-aerogel.com\/de\/wp-json\/wp\/v2\/media?parent=623"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/anchor-aerogel.com\/de\/wp-json\/wp\/v2\/categories?post=623"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/anchor-aerogel.com\/de\/wp-json\/wp\/v2\/tags?post=623"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}