{"id":623,"date":"2026-09-28T08:00:00","date_gmt":"2026-09-28T00:00:00","guid":{"rendered":"https:\/\/anchor-aerogel.com\/?p=623"},"modified":"2026-09-25T11:35:37","modified_gmt":"2026-09-25T03:35:37","slug":"applicazione-del-materassino-isolante-in-aerogel-su-tubazioni-a-bassa-temperatura","status":"publish","type":"post","link":"https:\/\/anchor-aerogel.com\/it\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/","title":{"rendered":"Coperta in aerogel per condotte criogeniche: eliminare la condensa e la CUI"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"623\" class=\"elementor elementor-623\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d4ae830 e-flex e-con-boxed e-con e-parent\" data-id=\"d4ae830\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-250ea0a elementor-widget elementor-widget-heading\" data-id=\"250ea0a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Applicazione del pannello isolante in aerogel su tubazioni a bassa temperatura<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2e297a3 e-flex e-con-boxed e-con e-parent\" data-id=\"2e297a3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-84f7f3d elementor-widget elementor-widget-text-editor\" data-id=\"84f7f3d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>I pannelli isolanti in aerogel possono fornire effetti di raffreddamento ottimali e valore economico di risparmio energetico a temperature fino a -200\u00b0C. Nell'industria petrolchimica, i pannelli isolanti in aerogel sono frequentemente utilizzati in tubazioni a bassa temperatura (generalmente riferendosi a tubazioni con temperature operative inferiori a -20\u00b0C).<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9b2210b e-flex e-con-boxed e-con e-parent\" data-id=\"9b2210b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-6921b8e e-con-full e-flex e-con e-child\" data-id=\"6921b8e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-66355fc elementor-widget elementor-widget-text-editor\" data-id=\"66355fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La misura di rivestire l'esterno delle tubazioni a bassa temperatura con materiali isolanti per ridurre la conduzione del calore esterno nella tubazione e mantenere la sua temperatura superficiale al di sopra del punto di rugiada, prevenendo cos\u00ec la condensa sulla superficie esterna, \u00e8 chiamata isolamento a freddo. Il materiale isolante applicato sull'esterno della tubazione \u00e8 solitamente indicato come materiale di isolamento a freddo.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb9d830 elementor-widget elementor-widget-text-editor\" data-id=\"fb9d830\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La selezione di materiali di isolamento a freddo adeguati \u00e8 essenziale per migliorare l'efficienza dell'isolamento a freddo, garantire la qualit\u00e0 del mezzo all'uscita e promuovere il risparmio energetico e la protezione ambientale.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-104ae9c e-con-full e-flex e-con e-child\" data-id=\"104ae9c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-138b5ef elementor-widget elementor-widget-image\" data-id=\"138b5ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"690\" height=\"517\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg\" class=\"attachment-large size-large wp-image-624\" alt=\"Applicazione del pannello isolante in aerogel su tubazioni a bassa temperatura\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg 690w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1-300x225.jpg 300w\" sizes=\"(max-width: 690px) 100vw, 690px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bd36ffb e-flex e-con-boxed e-con e-parent\" data-id=\"bd36ffb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8d6d3c1 elementor-widget elementor-widget-heading\" data-id=\"8d6d3c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Materiali Tradizionali di Isolamento a Freddo<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-521bd5c e-flex e-con-boxed e-con e-parent\" data-id=\"521bd5c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-c4b9443 e-con-full e-flex e-con e-child\" data-id=\"c4b9443\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8e04aae elementor-widget elementor-widget-image\" data-id=\"8e04aae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"459\" height=\"272\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/002-1-1.jpg\" class=\"attachment-large size-large wp-image-633\" alt=\"Applicazione del pannello isolante in aerogel su tubazioni a bassa temperatura\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/002-1-1.jpg 459w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/002-1-1-300x178.jpg 300w\" sizes=\"(max-width: 459px) 100vw, 459px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-07483f2 e-con-full e-flex e-con e-child\" data-id=\"07483f2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3c14693 elementor-widget elementor-widget-text-editor\" data-id=\"3c14693\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Attualmente, i materiali di isolamento a freddo comunemente utilizzati includono principalmente poliuretano, gomma-plastica, lana di roccia, ecc. Rispetto ai materiali in perlite precedentemente utilizzati, questi materiali sono stati notevolmente migliorati in termini di prestazioni e costruzione. Tuttavia, l'emergere dei materiali di isolamento a freddo in aerogel rappresenta un cambiamento qualitativo per il sistema esistente di isolamento criogenico.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0bc4de5 e-flex e-con-boxed e-con e-parent\" data-id=\"0bc4de5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c4ce887 elementor-widget elementor-widget-heading\" data-id=\"c4ce887\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Stato Attuale dei Materiali Isolanti Tradizionali:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-58e6939 e-flex e-con-boxed e-con e-parent\" data-id=\"58e6939\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-00671f6 e-con-full e-flex e-con e-child\" data-id=\"00671f6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-600541f elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"600541f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>I materiali isolanti tradizionali subiscono un rapido decadimento delle prestazioni isolanti, portando a costi di manutenzione elevati.<\/li><li>I materiali isolanti tradizionali hanno scarsi effetti di isolamento a freddo, con conseguente perdita significativa di capacit\u00e0 di raffreddamento.<\/li><li>I materiali isolanti tradizionali hanno un grande spessore di avvolgimento, che comporta molti inconvenienti per la progettazione di tubazioni disposte in modo denso. Le tubazioni sono suscettibili alla corrosione da acqua di condensa a causa dello scarso effetto di isolamento a freddo (CUI).<\/li><li>Gli strati di isolamento termico a freddo perdono facilmente la loro efficacia a causa dell'eccessiva condensa. I materiali organici hanno eccellenti propriet\u00e0 impermeabili ma non soddisfano i requisiti di protezione antincendio.<\/li><\/ul>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d5591b1 e-con-full e-flex e-con e-child\" data-id=\"d5591b1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2e41d0e elementor-widget elementor-widget-image\" data-id=\"2e41d0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"757\" height=\"449\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/003-2.jpg\" class=\"attachment-large size-large wp-image-640\" alt=\"Applicazione del pannello isolante in aerogel su tubazioni a bassa temperatura\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/003-2.jpg 757w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/003-2-300x178.jpg 300w\" sizes=\"(max-width: 757px) 100vw, 757px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4d76beb e-flex e-con-boxed e-con e-parent\" data-id=\"4d76beb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3fed082 elementor-widget elementor-widget-heading\" data-id=\"3fed082\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Materassino isolante in aerogel Anchor Tech<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1f7db90 e-flex e-con-boxed e-con e-parent\" data-id=\"1f7db90\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-bbaffe8 e-con-full e-flex e-con e-child\" data-id=\"bbaffe8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-32f54b9 elementor-widget elementor-widget-text-editor\" data-id=\"32f54b9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Il materassino isolante in aerogel Anchor Tech \u00e8 un flessibile materassino isolante per il freddo realizzato con tecnologia avanzata a nanocompositi, che combina aerogel di silice nano con materiali inorganici.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7d3990e e-flex e-con-boxed e-con e-parent\" data-id=\"7d3990e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a534c0e elementor-widget elementor-widget-heading\" data-id=\"a534c0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vantaggi del prodotto:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-48513b9 e-flex e-con-boxed e-con e-parent\" data-id=\"48513b9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-71b9d91 e-con-full e-flex e-con e-child\" data-id=\"71b9d91\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9a131b7 elementor-widget elementor-widget-image\" data-id=\"9a131b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"750\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/004.webp\" class=\"attachment-large size-large wp-image-645\" alt=\"Applicazione del pannello isolante in aerogel su tubazioni a bassa temperatura\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/004.webp 750w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/004-300x300.webp 300w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/004-150x150.webp 150w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3429421 e-con-full e-flex e-con e-child\" data-id=\"3429421\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b12fbb0 elementor-widget elementor-widget-image\" data-id=\"b12fbb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"629\" height=\"329\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/003-1.jpg\" class=\"attachment-large size-large wp-image-489\" alt=\"Informazioni sugli aerogel: ecco cosa vuoi sapere\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/003-1.jpg 629w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/003-1-300x157.jpg 300w\" sizes=\"(max-width: 629px) 100vw, 629px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c52056f e-flex e-con-boxed e-con e-parent\" data-id=\"c52056f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4658ea5 e-con-full e-flex e-con e-child\" data-id=\"4658ea5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6060fbc elementor-widget elementor-widget-text-editor\" data-id=\"6060fbc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>1. Presenta prestazioni eccezionali di isolamento termico a freddo con una conducibilit\u00e0 termica estremamente bassa, offrendo effetti di raffreddamento ottimali e valore economico di risparmio energetico anche a temperature fino a -200\u00b0C.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea392dc elementor-widget elementor-widget-text-editor\" data-id=\"ea392dc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>2. Il materassino isolante in aerogel ha una superiore resistenza al fuoco e propriet\u00e0 idrofobiche, inibendo efficacemente l'infiltrazione di acqua nella superficie della tubazione metallica, prevenendo la corrosione sotto isolamento (CUI) ed evitando una diminuzione dell'efficienza dell'isolamento termico a freddo dovuta all'infiltrazione di acqua.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c0bef68 e-con-full e-flex e-con e-child\" data-id=\"c0bef68\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9d6c97d elementor-widget elementor-widget-image\" data-id=\"9d6c97d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"226\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/008.gif\" class=\"attachment-large size-large wp-image-652\" alt=\"Applicazione del pannello isolante in aerogel su tubazioni a bassa temperatura\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e6b1705 e-flex e-con-boxed e-con e-parent\" data-id=\"e6b1705\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-e8c3611 e-con-full e-flex e-con e-child\" data-id=\"e8c3611\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-90701f0 elementor-widget elementor-widget-text-editor\" data-id=\"90701f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>3. Il materassino isolante in aerogel ha uno spessore inferiore del 75% rispetto a prodotti simili, consentendo un'installazione pi\u00f9 rapida e semplice di questo materiale isolante per il freddo, risparmiando tempo e costi.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ddc959 elementor-widget elementor-widget-text-editor\" data-id=\"1ddc959\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>4. Il materiale \u00e8 facile da tagliare, facilitando una costruzione comoda. \u00c8 sicuro, ecologico, non tossico e ha una lunga durata di servizio.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5480d8b e-con-full e-flex e-con e-child\" data-id=\"5480d8b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-acf2c66 elementor-widget elementor-widget-image\" data-id=\"acf2c66\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"663\" height=\"605\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009-1-1.jpg\" class=\"attachment-large size-large wp-image-666\" alt=\"Applicazione del pannello isolante in aerogel su tubazioni a bassa temperatura\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009-1-1.jpg 663w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009-1-1-300x274.jpg 300w\" sizes=\"(max-width: 663px) 100vw, 663px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-eaadc21 e-flex e-con-boxed e-con e-parent\" data-id=\"eaadc21\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eb7a987 elementor-widget elementor-widget-heading\" data-id=\"eb7a987\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Scenari di applicazione:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-48638d3 e-flex e-con-boxed e-con e-parent\" data-id=\"48638d3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-87560c4 e-con-full e-flex e-con e-child\" data-id=\"87560c4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-204e79f elementor-widget elementor-widget-text-editor\" data-id=\"204e79f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Il materassino isolante in aerogel Anchor Tech pu\u00f2 ridurre significativamente le perdite di freddo e le perdite di gas di evaporazione (BOG). \u00c8 adatto per apparecchiature di tubazioni criogeniche profonde, tubazioni a media e bassa temperatura, ventilatori per aria fredda\/tubi di scarico, ecc., come stoccaggio e trasporto di GNL, apparecchiature di stoccaggio di azoto liquido e ossigeno liquido o tubazioni di trasporto, ecc.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b305aef e-con-full e-flex e-con e-child\" data-id=\"b305aef\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09b29e1 elementor-widget elementor-widget-image\" data-id=\"09b29e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"571\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/010-2.jpg\" class=\"attachment-large size-large wp-image-659\" alt=\"Applicazione del pannello isolante in aerogel su tubazioni a bassa temperatura\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/010-2.jpg 826w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/010-2-300x214.jpg 300w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/010-2-768x549.jpg 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-abb73a0 e-flex e-con-boxed e-con e-parent\" data-id=\"abb73a0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b56f066 elementor-widget elementor-widget-heading\" data-id=\"b56f066\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Caso di applicazione:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4c49a1a e-flex e-con-boxed e-con e-parent\" data-id=\"4c49a1a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-c0c9e87 e-con-full e-flex e-con e-child\" data-id=\"c0c9e87\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e9810cc elementor-widget elementor-widget-image\" data-id=\"e9810cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"447\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/012-2.jpg\" class=\"attachment-large size-large wp-image-683\" alt=\"Applicazione del pannello isolante in aerogel su tubazioni a bassa temperatura\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/012-2.jpg 944w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/012-2-300x167.jpg 300w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/012-2-768x429.jpg 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cc69268 e-con-full e-flex e-con e-child\" data-id=\"cc69268\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d082ec8 elementor-widget elementor-widget-text-editor\" data-id=\"d082ec8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>C'erano due tubi dell'acqua refrigerata DN100 con isolamento inefficace e perdite lungo il passaggio verso l'angolo vicino alla sala di controllo dell'estremit\u00e0 A della stazione passeggeri di Tianhe sulla linea 3 della metropolitana di Guangzhou. La lunghezza totale \u00e8 di circa 40 metri. Li abbiamo sostituiti e rinnovati con il materassino isolante in aerogel per risolvere il problema delle perdite e garantire la sicurezza operativa.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-51a7ab6 e-flex e-con-boxed e-con e-parent\" data-id=\"51a7ab6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-5f82351 e-con-full e-flex e-con e-child\" data-id=\"5f82351\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3ff0d05 elementor-widget elementor-widget-text-editor\" data-id=\"3ff0d05\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>I materiali isolanti per raffreddamento di alta qualit\u00e0 non solo riducono il consumo energetico e minimizzano la perdita di capacit\u00e0 di raffreddamento, ma forniscono anche una garanzia per la produzione sicura e migliori benefici per le imprese. Il materassino isolante in aerogel di Anchor Tech, con le sue eccellenti prestazioni di isolamento per raffreddamento, resistenza alla fiamma, idrofobicit\u00e0, facilit\u00e0 di taglio e lunga durata, \u00e8 la scelta ideale per i clienti nel campo delle temperature criogeniche profonde che cercano migliori effetti di isolamento per raffreddamento e un minor consumo energetico.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-009a9a1 e-con-full e-flex e-con e-child\" data-id=\"009a9a1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9a18244 elementor-widget elementor-widget-image\" data-id=\"9a18244\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"492\" height=\"433\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/011-1.jpg\" class=\"attachment-large size-large wp-image-679\" alt=\"Applicazione del pannello isolante in aerogel su tubazioni a bassa temperatura\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/011-1.jpg 492w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/011-1-300x264.jpg 300w\" sizes=\"(max-width: 492px) 100vw, 492px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-09bd832 e-flex e-con-boxed e-con e-parent\" data-id=\"09bd832\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9702122 elementor-widget elementor-widget-html\" data-id=\"9702122\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2>Prodotti correlati in aerogel<\/h2><ul>\n<li><a href=\"https:\/\/anchor-aerogel.com\/it\/coperta-in-aerogel-criogenico-per-animali-domestici\/\">Coperta criogenica in aerogel PET AG20<\/a><\/li>\n<li><a href=\"https:\/\/anchor-aerogel.com\/it\/coperta-flessibile-in-aerogel\/\">Coperta isolante in aerogel flessibile AG65<\/a><\/li>\n<li><a href=\"https:\/\/anchor-aerogel.com\/it\/coperta-in-aerogel-di-fibra-ceramica\/\">Materassino in aerogel in fibra ceramica AG80<\/a><\/li>\n<\/ul>\n<p><a href=\"https:\/\/anchor-aerogel.com\/it\/contattaci\/\">Richiedi un preventivo per questi prodotti<\/a><\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7d07bed e-con-boxed e-flex e-con e-parent\" data-id=\"7d07bed\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2080298 elementor-widget elementor-widget-heading\" data-id=\"2080298\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Isolamento per Tubazioni in Aerogel: Specificare la Classe<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c0e022 elementor-widget elementor-widget-text-editor\" data-id=\"2c0e022\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Per l'isolamento delle tubazioni in aerogel, abbina la classe alla temperatura di linea: coperte in PET per criogenia sotto -40 \u00b0C, coperte flessibili per servizio generale e classi in fibra ceramica-aerogel sopra 650 \u00b0C.<\/p><!--kw-2026-09-25-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-14437ca e-con-boxed e-flex e-con e-parent\" data-id=\"14437ca\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5e7f6f1 elementor-widget elementor-widget-heading\" data-id=\"5e7f6f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Come Installare la Coperta in Aerogel sulle Tubazioni<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1c96bd elementor-widget elementor-widget-text-editor\" data-id=\"d1c96bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Per installare la coperta in aerogel sulle tubazioni, avvolgi la coperta flessibile aderente, fissala con fasce o filo metallico, quindi aggiungi una barriera al vapore e una guaina protettiva. Una corretta barriera al vapore \u00e8 ci\u00f2 che previene la corrosione sotto l'isolamento durante la vita utile. Questa breve guida all'installazione si applica alla maggior parte dei tracciati delle tubazioni.<\/p><!--kw-2026-09-25-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Materassino isolante in aerogel per tubazioni a bassa temperatura. Confronta l'aerogel con i materiali isolanti tradizionali per il freddo e consulta i dati sulle prestazioni.<\/p>","protected":false},"author":1,"featured_media":624,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9],"tags":[],"class_list":["post-623","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI - Anchor Aerogel<\/title>\n<meta name=\"description\" content=\"Cold insulation must keep the pipe surface above the dew point and stay dry. Aerogel&#039;s hydrophobicity and thin profile make it ideal for \u221220 \u00b0C to \u2212200 \u00b0C lines. \u2014 Anchor Technology Co., Ltd.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/anchor-aerogel.com\/it\/applicazione-del-materassino-isolante-in-aerogel-su-tubazioni-a-bassa-temperatura\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI - Anchor Aerogel\" \/>\n<meta property=\"og:description\" content=\"Cold insulation must keep the pipe surface above the dew point and stay dry. Aerogel&#039;s hydrophobicity and thin profile make it ideal for \u221220 \u00b0C to \u2212200 \u00b0C lines. \u2014 Anchor Technology Co., Ltd.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/anchor-aerogel.com\/it\/applicazione-del-materassino-isolante-in-aerogel-su-tubazioni-a-bassa-temperatura\/\" \/>\n<meta property=\"og:site_name\" content=\"Anchor Aerogel\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-28T00:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"690\" \/>\n\t<meta property=\"og:image:height\" content=\"517\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Anchor Tech Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"Anchor Tech Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/\"},\"author\":{\"name\":\"Anchor Tech Team\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#\\\/schema\\\/person\\\/1fb2a61c6b00b9a4e340d577998a9daf\"},\"headline\":\"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI\",\"datePublished\":\"2026-09-28T00:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/\"},\"wordCount\":394,\"publisher\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/001-1.jpg\",\"articleSection\":[\"Application\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/\",\"name\":\"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI - Anchor Aerogel\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/001-1.jpg\",\"datePublished\":\"2026-09-28T00:00:00+00:00\",\"description\":\"Cold insulation must keep the pipe surface above the dew point and stay dry. Aerogel's hydrophobicity and thin profile make it ideal for \u221220 \u00b0C to \u2212200 \u00b0C lines. \u2014 Anchor Technology Co., Ltd.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#primaryimage\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/001-1.jpg\",\"contentUrl\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/001-1.jpg\",\"width\":690,\"height\":517,\"caption\":\"Application of Aerogel Insulation Blanket on Low-Temperature Pipelines\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/anchor-aerogel.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#website\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/\",\"name\":\"Anchor Aerogel\",\"description\":\"Advanced aerogel thermal insulation materials and blankets for extreme environments.\",\"publisher\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/anchor-aerogel.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#organization\",\"name\":\"Anchor Aerogel\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/wechat-image-logo.jpg\",\"contentUrl\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/wechat-image-logo.jpg\",\"width\":837,\"height\":405,\"caption\":\"Anchor Aerogel\"},\"image\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#\\\/schema\\\/person\\\/1fb2a61c6b00b9a4e340d577998a9daf\",\"name\":\"Anchor Tech Team\",\"sameAs\":[\"https:\\\/\\\/anchor-aerogel.com\"],\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/it\\\/author\\\/164868441qq-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Coperta in aerogel per condotte criogeniche: eliminare la condensa e la CUI - Anchor Aerogel","description":"L'isolamento a freddo deve mantenere la superficie del tubo al di sopra del punto di rugiada e rimanere asciutto. L'idrofobicit\u00e0 e il profilo sottile dell'aerogel lo rendono ideale per linee da \u221220 \u00b0C a \u2212200 \u00b0C. \u2014 Anchor Technology Co., Ltd.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/anchor-aerogel.com\/it\/applicazione-del-materassino-isolante-in-aerogel-su-tubazioni-a-bassa-temperatura\/","og_locale":"it_IT","og_type":"article","og_title":"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI - Anchor Aerogel","og_description":"Cold insulation must keep the pipe surface above the dew point and stay dry. Aerogel's hydrophobicity and thin profile make it ideal for \u221220 \u00b0C to \u2212200 \u00b0C lines. \u2014 Anchor Technology Co., Ltd.","og_url":"https:\/\/anchor-aerogel.com\/it\/applicazione-del-materassino-isolante-in-aerogel-su-tubazioni-a-bassa-temperatura\/","og_site_name":"Anchor Aerogel","article_published_time":"2026-09-28T00:00:00+00:00","og_image":[{"width":690,"height":517,"url":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg","type":"image\/jpeg"}],"author":"Anchor Tech Team","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"Anchor Tech Team","Tempo di lettura stimato":"2 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#article","isPartOf":{"@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/"},"author":{"name":"Anchor Tech Team","@id":"https:\/\/anchor-aerogel.com\/#\/schema\/person\/1fb2a61c6b00b9a4e340d577998a9daf"},"headline":"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI","datePublished":"2026-09-28T00:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/"},"wordCount":394,"publisher":{"@id":"https:\/\/anchor-aerogel.com\/#organization"},"image":{"@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#primaryimage"},"thumbnailUrl":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg","articleSection":["Application"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/","url":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/","name":"Coperta in aerogel per condotte criogeniche: eliminare la condensa e la CUI - Anchor Aerogel","isPartOf":{"@id":"https:\/\/anchor-aerogel.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#primaryimage"},"image":{"@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#primaryimage"},"thumbnailUrl":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg","datePublished":"2026-09-28T00:00:00+00:00","description":"L'isolamento a freddo deve mantenere la superficie del tubo al di sopra del punto di rugiada e rimanere asciutto. L'idrofobicit\u00e0 e il profilo sottile dell'aerogel lo rendono ideale per linee da \u221220 \u00b0C a \u2212200 \u00b0C. \u2014 Anchor Technology Co., Ltd.","breadcrumb":{"@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#primaryimage","url":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg","contentUrl":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/001-1.jpg","width":690,"height":517,"caption":"Application of Aerogel Insulation Blanket on Low-Temperature Pipelines"},{"@type":"BreadcrumbList","@id":"https:\/\/anchor-aerogel.com\/application-of-aerogel-insulation-blanket-on-low-temperature-pipelines\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/anchor-aerogel.com\/"},{"@type":"ListItem","position":2,"name":"Aerogel Blanket for Cryogenic Pipelines: End Condensation and CUI"}]},{"@type":"WebSite","@id":"https:\/\/anchor-aerogel.com\/#website","url":"https:\/\/anchor-aerogel.com\/","name":"Aerogel di ancoraggio","description":"Materiali e coperte isolanti termici in aerogel avanzato per ambienti estremi.","publisher":{"@id":"https:\/\/anchor-aerogel.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/anchor-aerogel.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/anchor-aerogel.com\/#organization","name":"Aerogel di ancoraggio","url":"https:\/\/anchor-aerogel.com\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/anchor-aerogel.com\/#\/schema\/logo\/image\/","url":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/07\/wechat-image-logo.jpg","contentUrl":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/07\/wechat-image-logo.jpg","width":837,"height":405,"caption":"Anchor Aerogel"},"image":{"@id":"https:\/\/anchor-aerogel.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/anchor-aerogel.com\/#\/schema\/person\/1fb2a61c6b00b9a4e340d577998a9daf","name":"Anchor Tech Team","sameAs":["https:\/\/anchor-aerogel.com"],"url":"https:\/\/anchor-aerogel.com\/it\/author\/164868441qq-com\/"}]}},"_links":{"self":[{"href":"https:\/\/anchor-aerogel.com\/it\/wp-json\/wp\/v2\/posts\/623","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/anchor-aerogel.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/anchor-aerogel.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/anchor-aerogel.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/anchor-aerogel.com\/it\/wp-json\/wp\/v2\/comments?post=623"}],"version-history":[{"count":1,"href":"https:\/\/anchor-aerogel.com\/it\/wp-json\/wp\/v2\/posts\/623\/revisions"}],"predecessor-version":[{"id":4320,"href":"https:\/\/anchor-aerogel.com\/it\/wp-json\/wp\/v2\/posts\/623\/revisions\/4320"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/anchor-aerogel.com\/it\/wp-json\/wp\/v2\/media\/624"}],"wp:attachment":[{"href":"https:\/\/anchor-aerogel.com\/it\/wp-json\/wp\/v2\/media?parent=623"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/anchor-aerogel.com\/it\/wp-json\/wp\/v2\/categories?post=623"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/anchor-aerogel.com\/it\/wp-json\/wp\/v2\/tags?post=623"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}