{"id":2962,"date":"2026-03-04T05:55:03","date_gmt":"2026-03-03T21:55:03","guid":{"rendered":"https:\/\/anchor-aerogel.com\/?p=2962"},"modified":"2026-10-28T12:20:30","modified_gmt":"2026-10-28T04:20:30","slug":"organska-vlaknasta-fleksibilna-aerogel-odeja-ag40","status":"publish","type":"post","link":"https:\/\/anchor-aerogel.com\/sl\/organic-fiber-flexible-aerogel-blanket-ag40\/","title":{"rendered":"Aerogel izolacijska odeja iz organskih vlaken (AG40)"},"content":{"rendered":"\t\t
\n\t\t\t\t
\n\t\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t\t

Organic Fiber Flexible Aerogel Blanket (AG40)<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t
\n\t\t\t\t\t
\n\t\t
\n\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\"Organic\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t
\n\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t\t\t\t\t\t

Product Description<\/b><\/h2>

Organic Fiber Flexible Aerogel Blanket\uff08AG40\uff09is a new type of high-temperature thermal insulation material composed of special flame-retardant fiber wool and microporous silica powder filler.<\/p>

The material is a flexible insulation solution produced through a vacuum high-pressure drying process. It combines fiber wool\u2014made from a raw material blend of para-position and meta-position structures of p-phenylenediamine and terephthalic acid\u2014with a composite of porous oxidized silica (silicon dioxide).<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t

\n\t\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t\t\t\t\t\t

Product Features<\/b><\/h2>

1.Flame Retardant, High Temperature Resistant, Electrically Insulating<\/b><\/p>

2.Ultra-Low Thermal Conductivity:<\/b> as low as 0.019W\/(m\u00b7K)<\/p>

3.Customizable Thickness:<\/b> 0.5\u201315 mm or as required<\/p>

4.Flexible Form:<\/b> available in rolls or sheets, customizable<\/p>

5.Easy Processing:<\/b> can be die-cut, edge-wrapped, laminated with double-sided tape or film, and cut to specific requirements<\/p>

6.Environmentally Compliant:<\/b> meets RoHS directive requirements<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t

\n\t\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t\t\t\t\t\t

Product Applications<\/b><\/h2>
  • Aerospace and aviation<\/li>
  • Robotics<\/li>
  • E-cigarettes<\/li>
  • Battery energy storage<\/li>
  • RVs and automobiles<\/li>
  • Power battery module spacing<\/li>
  • Wearable devices<\/li>
  • Household appliances<\/li>
  • Smart terminals<\/li>
  • Heating elements<\/li>
  • Thermal insulation for mechanical equipment<\/li><\/ul>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t
    \n\t\t\t\t\t
    \n\t\t\t\t
    \n\t\t\t\t
    \n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\"Product\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t
    \n\t\t\t\t\t
    \n\t\t\t\t
    \n\t\t\t\t
    \n\t\t\t\t\t

    Product Parameters<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t
    \n\t\t\t\t\t
    \n\t\t\t\t
    \n\t\t\t\t
    \n\t\t\t\t\t\t\t\t\t
    <\/colgroup>

    Item & Property<\/b><\/p><\/th>

    Range<\/b><\/p><\/th>

    Test Standard<\/b><\/p><\/th><\/tr><\/thead>

    Thickness( mm) <\/p>

    (Tolerance\u00b11 0 % )<\/p><\/td>

    0.5mm\/1mm\/1.5mm\/2mm\/2.5mm\/mm\/ 4mm\/5mm\/6mm\/7mm\/8mm\/9mm\/10mm\/ 15mm<\/p><\/td>

    ASTMD374<\/p><\/td><\/tr>

    Thermal conductivity \uff08W\/K\u00b7m\uff09<\/p><\/td>

    0.015-0.019<\/p><\/td>

    ASTM D5470\/TPS<\/p><\/td><\/tr>

    Service Temperature(\u2103)<\/p><\/td>

    -100 – 400<\/p><\/td>

    Standard<\/p><\/td><\/tr>

    Vertical Flame Rating<\/p><\/td>

    V- O Equivalent<\/p><\/td>

    UL94<\/p><\/td><\/tr>

    Density\uff08 k g \/ m \u00b3 \uff09<\/p><\/td>

    200\u00b120<\/p><\/td>

    ASTMD3574<\/p><\/td><\/tr>

    Water absorption<\/p><\/td>

    8%<\/p><\/td>

    GB\/T5480<\/p><\/td><\/tr>

    Shear Strength\uff0825\u2103\uff09<\/p>

    \uff08 MPa \uff09<\/p><\/td>

    Min\u22650.7<\/p><\/td>

    \/<\/p><\/td><\/tr>

    Shear modulus\uff0825\u2103\uff09 ( MPa )<\/p><\/td>

    Min\u22651.5<\/p><\/td>

    \/<\/p><\/td><\/tr>

    Insulation resistance<\/p><\/td>

    2.02\u00d710\u00b9\u00b9<\/p><\/td>

    GB\/T31838.4-2019(Voltage 100VDC)<\/p><\/td><\/tr>

    Dimensions (Rolls)<\/p><\/td>

    500mm*50m\uff0c1200mm*40m\uff0c900mm*40m\uff0c500mm*40m<\/p>

    (Note:<\/b> Roll length varies depending on thickness, ranging from 15\u202fm to 80\u202fm)<\/p><\/td><\/tr><\/tbody><\/table><\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t

    \n\t\t\t\t\t
    \n\t\t\t\t
    \n\t\t\t\t
    \n\t\t\t\t\t\t\t\t\t

    Precautions \/ Handling Instructions<\/b><\/h2>

    * Please use the product within the specified period. Dimensions may vary due to humidity. When accurate sizing is required, the product must be stored and managed under specific conditions for the designated period, and measurements should be taken in the same environment.
    Example:<\/i> Dimensions measured after storage at 25\u202f\u00b1\u202f2\u202f\u00b0C and 50\u202f\u00b1\u202f20\u202f% RH are considered the standard values.<\/p>

    * Appearance limits are based on internal company standards. If in doubt, please contact our company immediately.<\/p>

    * To avoid performance degradation, do not store the product under the following environments or conditions:<\/p>

    \u2460Areas with corrosive gases such as sea breeze, chlorine, hydrogen sulfide, ammonia, sulfur dioxide, nitrogen oxides, etc.<\/p>

    \u2461Locations exposed to ultraviolet (UV) light. (Storage in a shaded or cool place is recommended.)<\/p>

    \u2462Temperatures outside the specified storage range.<\/p>

    \u2463Under load-free conditions.<\/p>

    * For products designed with adhesion as a functional requirement, if the storage period has expired, please check the adhesive properties before use.<\/p>

    * Regardless of the intended application, for high-reliability equipment, we recommend implementing protective measures such as protective circuits or redundant circuits. Customers should perform safety testing to ensure equipment protection.<\/p>

    * If the product specified in this datasheet is used for applications requiring special quality or high reliability, where failure or malfunction may directly threaten life or cause bodily harm (e.g., aerospace equipment, transportation systems, combustion devices, medical equipment, disaster prevention systems, safety devices, etc.), the specifications must be confirmed for that intended use. Please consult our company representative before use.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t

    \n\t\t\t\t\t
    \n\t\t\t\t
    \n\t\t\t\t
    \n\t\t\t\t\t

    Manufacturer & Engineering Notes<\/h2>

    Manufacturing & Project Experience<\/h3>

    Anchor-Aerogel manufactures AG40 through a vacuum high-pressure drying process that bonds microporous silica to flame-retardant organic fiber wool. Because this product is typically converted rather than installed in bulk, our support model is drawing-driven: customers submit dimensions, tolerances, and lamination requirements, and we supply samples, die-cut prototypes, and production lots to match. Test data referenced on this page follows published standards including ASTM D374, ASTM D5470, UL94, and GB\/T methods. Shelf-life, storage, and measurement-environment requirements in the datasheet are part of our standard delivery documentation for OEM customers.<\/p>

    Engineering Boundaries & Custom Options<\/h3>

    AG40 covers a standard thickness range of 0.5-15 mm with \u00b110% tolerance and thermal conductivity of 0.015-0.019 W\/(m\u00b7K); service temperature is bounded at -100\u00b0C to 400\u00b0C, and water absorption is published at 8%, which should be considered in humid or condensing designs. Standard material is supplied in rolls or sheets; die-cutting, edge-wrapping, and tape or film lamination are customized options quoted per drawing. The product is RoHS compliant and V-0 equivalent, but dimensions are humidity-sensitive and high-reliability applications require use-specific specification confirmation, as stated in the datasheet.<\/p><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t

    \n\t\t\t\t\t
    \n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t
    \n\t\t\t\t\t
    \n\t\t\t\t
    \n\t\t\t\t
    \n\t\t\t\t\t