{"id":901,"date":"2026-10-01T11:00:00","date_gmt":"2026-10-01T03:00:00","guid":{"rendered":"https:\/\/anchor-aerogel.com\/?p=901"},"modified":"2026-09-28T12:00:55","modified_gmt":"2026-09-28T04:00:55","slug":"anchor-tech-izolacija-cevovodov-iz-aerogela","status":"publish","type":"post","link":"https:\/\/anchor-aerogel.com\/sl\/anchor-tech-aerogel-pipeline-insulation\/","title":{"rendered":"Aerogel za izolacijo industrijskih cevovodov: ena tretjina debeline, enaka u\u010dinkovitost"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"901\" class=\"elementor elementor-901\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7822415 e-flex e-con-boxed e-con e-parent\" data-id=\"7822415\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-73b9c81 elementor-widget elementor-widget-heading\" data-id=\"73b9c81\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Applications of Aerogel Insulation Materials in the Pipeline Industry<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-332f4e8 e-flex e-con-boxed e-con e-parent\" data-id=\"332f4e8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ae2ac4d elementor-widget elementor-widget-heading\" data-id=\"ae2ac4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Current Status of Pipeline Insulation:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c288ab9 e-flex e-con-boxed e-con e-parent\" data-id=\"c288ab9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e8152f4 elementor-widget elementor-widget-text-editor\" data-id=\"e8152f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In the present industrial heating pipelines, temperatures range from 50\u00a0 degrees to 600 degrees. Silica-alumina magnesia materials and glass fiber materials are widely used in the insulation projects of these pipelines. Approximately 30 years ago, insulation projects almost exclusively employed rock wool and mineral wool materials. However, in today&#8217;s industrial insulation projects, rock wool insulation has been phased out. Despite similar construction and waterproofing performance, the primary reason for its elimination is the gap in thermal conductivity. The following are the thermal conductivity coefficients of various materials at different temperatures.<\/p>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-165af81 e-flex e-con-boxed e-con e-parent\" data-id=\"165af81\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-73ab8b4 elementor-widget elementor-widget-image\" data-id=\"73ab8b4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"469\" height=\"295\" src=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009.webp\" class=\"attachment-large size-large wp-image-533\" alt=\"About Aerogels, Here\u2019s What You Want to Know\" srcset=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009.webp 469w, https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009-300x189.webp 300w\" sizes=\"(max-width: 469px) 100vw, 469px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dbc3553 e-flex e-con-boxed e-con e-parent\" data-id=\"dbc3553\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-48356cf elementor-widget elementor-widget-heading\" data-id=\"48356cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Current Issues in Pipeline Insulation Projects:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f77878e e-flex e-con-boxed e-con e-parent\" data-id=\"f77878e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fc2e5ec elementor-widget elementor-widget-text-editor\" data-id=\"fc2e5ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Unreasonable insulation structure, non-standard insulation thickness, and inadequate insulation construction.<\/li><li>Susceptibility to deformation, settlement, poor thermal stability, high damage rates, leading to poor long-term insulation effects that cannot meet process requirements.<\/li><li>Ineffective insulation with a noticeable decline, causing increased maintenance costs for insulation projects and higher equipment operating expenses.<\/li><li>Limited lifespan of only 3 to 5 years, requiring complete replacement at the end of its service life.<\/li><li>Incomplete waterproofing, prone to water absorption and corrosion of the pipeline.<\/li><li>For pipes with temperatures exceeding 100 degrees, the insulation layer needs to be at least &gt;200mm thick, resulting in high thermal energy loss due to the high heat flow density of the pipeline.<\/li><\/ul>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-537e6b3 e-flex e-con-boxed e-con e-parent\" data-id=\"537e6b3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d328ec0 elementor-widget elementor-widget-heading\" data-id=\"d328ec0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Benefits of Aerogel Materials:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ccea04a e-flex e-con-boxed e-con e-parent\" data-id=\"ccea04a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d5ad7e0 elementor-widget elementor-widget-text-editor\" data-id=\"d5ad7e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Thermal insulation effect is 2-5 times that of traditional insulation materials, with more significant advantages at high temperatures, and a longer lifespan.<\/li><li>Material is hydrophobic, effectively preventing moisture from entering the pipeline and equipment, and it possesses Class A1 fire resistance.<\/li><li>Lightweight, easy to cut, sew, and adapt to various shapes of pipelines and equipment insulation, with less installation time and labor required.<\/li><li>Reduced wrapping volume and lighter weight significantly lower the transportation costs of insulation materials.<\/li><li>Provides sound absorption, noise reduction, and vibration damping functions while insulating equipment, improving environmental quality, and protecting devices.<\/li><li>Only 1\/2 to 1\/5 of the thickness is needed to achieve the same thermal insulation effect as traditional materials, resulting in minimal heat loss and high space utilization.<\/li><\/ul>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-679fbcc e-flex e-con-boxed e-con e-parent\" data-id=\"679fbcc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cb625e8 elementor-widget elementor-widget-text-editor\" data-id=\"cb625e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"an2-tw an2-mid an2-t620\"><table class=\"an-tbl an2-comp\"><colgroup><col style=\"width:45.961%\"><col style=\"width:12.364%\"><col style=\"width:15.419%\"><col style=\"width:12.364%\"><col style=\"width:13.891%\"><\/colgroup><tbody><tr><td>Thermal conductivity<br>mw\/m\u00b7k<\/td><td>25\u2103.<\/td><td>100 \u2103\u3002<\/td><td>200\u2103<\/td><td>400\u2103\u3002<\/td><\/tr><tr><td>Aerogel felt<\/td><td>18<\/td><td>21<\/td><td>25<\/td><td>34<\/td><\/tr><tr><td>ceramic fiber blanket\u00a0<\/td><td>37.<\/td><td>55<\/td><td>72<\/td><td rowspan=\"2\">110<\/td><\/tr><tr><td>glass fibre<\/td><td>42<\/td><td>50.<\/td><td>70.<\/td><\/tr><tr><td>Rock wool<\/td><td>55<\/td><td rowspan=\"2\">70<\/td><td>92<\/td><td>140<\/td><\/tr><tr><td>Foam material<\/td><td>36.<\/td><td colspan=\"2\">\u3000<\/td><\/tr><\/tbody><\/table><\/div>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2be89b5 e-flex e-con-boxed e-con e-parent\" data-id=\"2be89b5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-26ddc0b elementor-widget elementor-widget-heading\" data-id=\"26ddc0b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Performance Comparison between Aerogel Composite Insulation Materials and Other Insulation Materials:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5dda414 e-flex e-con-boxed e-con e-parent\" data-id=\"5dda414\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c06fe17 elementor-widget elementor-widget-text-editor\" data-id=\"c06fe17\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"an2-tw an2-full\"><table class=\"an-tbl an2-comp\"><colgroup><col style=\"width:9.516%\"><col style=\"width:35.116%\"><col style=\"width:27.684%\"><col style=\"width:27.684%\"><\/colgroup><tbody><tr><td>\u00a0<\/td><td>Aerogel composite insulation blanket<\/td><td>ceramic fiber\u00a0<\/td><td>Rock wool<\/td><\/tr><tr><td>Thermal conductivity <br>(at room temperature)<\/td><td>18<\/td><td>36<\/td><td>55<\/td><\/tr><tr><td>Thermal conductivity at 350 \u2103<\/td><td>30<\/td><td>110<\/td><td>130<\/td><\/tr><tr><td>Insulation thickness at 350 \u2103<\/td><td>30mm<\/td><td>100mm<\/td><td>110mm<\/td><\/tr><tr><td>Bulk density, kg\/m3<\/td><td>200<\/td><td>128<\/td><td>110<\/td><\/tr><tr><td>Waterproofness<\/td><td>Hydrophobicity rate \u2265 99%, no special waterproofing measures required<\/td><td colspan=\"2\">Incomplete waterproofing, prone to water absorption, moisture absorption, and corrosion of pipelines. The surface of the protective plate needs to be sprayed with metal sealant for waterproofing<\/td><\/tr><tr><td>Insulation of tees and valves<\/td><td>Detachable insulation sleeve, with good insulation effect and convenient use.<\/td><td colspan=\"2\">The filling method or insulation box has poor insulation effect.<\/td><\/tr><tr><td>service life<\/td><td>20Years<\/td><td>3~5Years<\/td><td>3~5Years<\/td><\/tr><tr><td>Usage process<\/td><td>Good overall integrity, with good seismic and tensile resistance, and no particle accumulation, settlement or other phenomena during use.<\/td><td colspan=\"2\">The material structure is loose, and factors such as self weight, equipment vibration, and water ingress can easily lead to material disintegration and settlement, resulting in a significant decrease in insulation effectiveness and severe excessive heat loss.\u00a0<\/td><\/tr><tr><td>Using Comparison<\/td><td>Using a smaller thickness can reduce the insulation thickness of the pipeline, reduce the spacing between steam pipelines, and reduce the area of the factory building<\/td><td colspan=\"2\">The insulation layer is thick, and there are easy gaps at the overlapping points. A higher expansion and contraction coefficient can easily make the gaps become thermal bridges, which are more obvious after vibration<\/td><\/tr><\/tbody><\/table><\/div>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6ab31f2 e-flex e-con-boxed e-con e-parent\" data-id=\"6ab31f2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-180b4bf elementor-widget elementor-widget-heading\" data-id=\"180b4bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Economic Benefits Comparison between Aerogel Composite Insulation Materials and Traditional Insulation Materials:\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-12e5482 e-flex e-con-boxed e-con e-parent\" data-id=\"12e5482\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-98de763 elementor-widget elementor-widget-text-editor\" data-id=\"98de763\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"an2-tw an2-full\"><table class=\"an-tbl an2-comp\"><colgroup><col style=\"width:48.029%\"><col style=\"width:31.013%\"><col style=\"width:20.958%\"><\/colgroup><tbody><tr><td>\u3000<\/td><td>Aerogel composite insulation blanket<\/td><td>Composite silicate felt<\/td><\/tr><tr><td>Expected surface temperature (\u2103)<\/td><td>35<\/td><td>35<\/td><\/tr><tr><td>Insulation material thickness mm<\/td><td>120<\/td><td>300.<\/td><\/tr><tr><td><span data-sent-id=\"7BXw3QELqz\">Total volume of insulation layer m \u00b3<\/span><\/td><td>83.<\/td><td>377<\/td><\/tr><tr><td>Main material costs (10000 yuan)<\/td><td>85<\/td><td>45.<\/td><\/tr><tr><td>Construction cost and auxiliary material cost (10000 yuan)<\/td><td>11<\/td><td>20.<\/td><\/tr><tr><td>Pipeline heat flux density (W\/m)<\/td><td>130<\/td><td>300<\/td><\/tr><tr><td>Heat loss ratio<\/td><td>1<\/td><td>3.<\/td><\/tr><tr><td>Total thermal energy loss (%)<\/td><td>3%<\/td><td>10%<\/td><\/tr><\/tbody><\/table><\/div>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2d9f72d e-flex e-con-boxed e-con e-parent\" data-id=\"2d9f72d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-77587bc elementor-widget elementor-widget-text-editor\" data-id=\"77587bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"flex-1 overflow-hidden\"><div class=\"react-scroll-to-bottom--css-nslva-79elbk h-full\"><div class=\"react-scroll-to-bottom--css-nslva-1n7m0yu\"><div class=\"flex flex-col text-sm pb-9\"><div class=\"w-full text-token-text-primary\" data-testid=\"conversation-turn-37\"><div class=\"px-4 py-2 justify-center text-base md:gap-6 m-auto\"><div class=\"flex flex-1 text-base mx-auto gap-3 md:px-5 lg:px-1 xl:px-5 md:max-w-3xl lg:max-w-[40rem] xl:max-w-[48rem] group final-completion\"><div class=\"relative flex w-full flex-col agent-turn\"><div class=\"flex-col gap-1 md:gap-3\"><div class=\"flex flex-grow flex-col max-w-full\"><div class=\"min-h-[20px] text-message flex flex-col items-start gap-3 whitespace-pre-wrap break-words [.text-message+&amp;]:mt-5 overflow-x-auto\" data-message-author-role=\"assistant\" data-message-id=\"2c259774-1fc4-402f-aa9c-cac1f3873b75\"><div class=\"markdown prose w-full break-words dark:prose-invert light\"><p><em>Note: (Example calculation based on a 1 km, 100 mm diameter, 300-degree heating pipeline.) In practical applications, the composite silicate felt&#8217;s insulation effectiveness will deteriorate after 2 to 3 months, leading to increased heat loss.<\/em><\/p><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<!--an2:v2-2026-09-25d-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-458b066 e-flex e-con-boxed e-con e-parent\" data-id=\"458b066\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-27e5cb2 elementor-widget elementor-widget-html\" data-id=\"27e5cb2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2>Related Aerogel Products<\/h2><ul>\n<li><a href=\"https:\/\/anchor-aerogel.com\/flexible-aerogel-blanket\/\">AG65 Flexible Aerogel Insulation Blanket<\/a><\/li>\n<li><a href=\"https:\/\/anchor-aerogel.com\/ceramic-fiber-aerogel-blanket\/\">AG80 Ceramic Fiber Aerogel Blanket<\/a><\/li>\n<li><a href=\"https:\/\/anchor-aerogel.com\/pet-cryogenic-aerogel-blanket\/\">AG20 PET Cryogenic Aerogel Blanket<\/a><\/li>\n<\/ul>\n<p><a href=\"https:\/\/anchor-aerogel.com\/contact-us\/\">Request a Quotation for These Products<\/a><\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-930a02b e-flex e-con-boxed e-con e-parent\" data-id=\"930a02b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-68e1a62 elementor-widget elementor-widget-html\" data-id=\"68e1a62\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<style>.anchor-sample-faq{margin:34px 0;}.anchor-sample-faq h2{margin:0 0 6px;font-size:26px;color:#1a1a1a;}.anchor-sample-faq .sf-intro{font-style:italic;color:#555;margin:0 0 14px;}.anchor-sample-faq details.at-sf-item{margin:14px 0;padding:14px 18px;background:#fafafa;border-left:3px solid #c9a227;border-radius:4px;}.anchor-sample-faq summary{font-weight:600;cursor:pointer;color:#1a1a1a;font-size:16px;line-height:1.5;}.anchor-sample-faq details.at-sf-item p{margin:10px 0 0;line-height:1.7;color:#333;}<\/style>\n<div class=\"anchor-sample-faq\">\n  <h2>Sample Request FAQs<\/h2>\n  <p class=\"sf-intro\">Quick answers about requesting and receiving free samples from Anchor-tech.<\/p>\n  <details class=\"at-sf-item\"><summary>Can you provide samples?<\/summary><p>Yes. Please share some basic information about your project with us \u2014 for example, where the material will be used and at what operating temperature. Rest assured this is only so we can help you choose the most suitable material, model, and specification. We will never disclose your project details to any third party.<\/p><\/details>\n  <details class=\"at-sf-item\"><summary>Can we still request samples if we cannot disclose any project information?<\/summary><p>No. If you are unwilling to share any information about your project, we are not obligated to support your R&amp;D effort. Please respect the labor involved: preparing each sample requires a dedicated colleague and is quite time-consuming. Moreover, without knowing where and how you intend to use our product, we cannot even determine whether it is suitable for your application.<\/p><\/details>\n  <details class=\"at-sf-item\"><summary>Are samples free, and how much can I request?<\/summary><p>We provide 2 free samples of aerogel blanket, each sized 150 mm \u00d7 200 mm \u00d7 T (or A4 size). If you need a larger quantity or many pieces, please let us know the reason \u2014 we are glad to support you. However, if you have never seen our sample before and only want to take a look, please do not casually request large amounts. A dedicated colleague must prepare every sample, which takes considerable effort. You may first take a look; once you confirm it is likely suitable for your project, you can request more from us.<\/p><\/details>\n  <details class=\"at-sf-item\"><summary>Who pays for shipping?<\/summary><p>Shipping costs must be borne by the customer. Please provide us with your FedEx account number and the recipient information (including name, address, phone number, postal code, etc.), and we will arrange the shipment for you.<\/p><\/details>\n  <details class=\"at-sf-item\"><summary>How long does it take to prepare samples?<\/summary><p>If the item is in stock, preparation generally takes 3\u20137 days. If it is out of stock and requires custom manufacturing, it takes 1\u20132 weeks. We will prepare your samples as quickly as possible.<\/p><\/details>\n<\/div>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Can you provide samples?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. Please share some basic information about your project with us \u2014 for example, where the material will be used and at what operating temperature. Rest assured this is only so we can help you choose the most suitable material, model, and specification. We will never disclose your project details to any third party.\"}}, {\"@type\": \"Question\", \"name\": \"Can we still request samples if we cannot disclose any project information?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. If you are unwilling to share any information about your project, we are not obligated to support your R&D effort. Please respect the labor involved: preparing each sample requires a dedicated colleague and is quite time-consuming. Moreover, without knowing where and how you intend to use our product, we cannot even determine whether it is suitable for your application.\"}}, {\"@type\": \"Question\", \"name\": \"Are samples free, and how much can I request?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"We provide 2 free samples of aerogel blanket, each sized 150 mm \u00d7 200 mm \u00d7 T (or A4 size). If you need a larger quantity or many pieces, please let us know the reason \u2014 we are glad to support you. However, if you have never seen our sample before and only want to take a look, please do not casually request large amounts. A dedicated colleague must prepare every sample, which takes considerable effort. You may first take a look; once you confirm it is likely suitable for your project, you can request more from us.\"}}, {\"@type\": \"Question\", \"name\": \"Who pays for shipping?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Shipping costs must be borne by the customer. Please provide us with your FedEx account number and the recipient information (including name, address, phone number, postal code, etc.), and we will arrange the shipment for you.\"}}, {\"@type\": \"Question\", \"name\": \"How long does it take to prepare samples?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"If the item is in stock, preparation generally takes 3\u20137 days. If it is out of stock and requires custom manufacturing, it takes 1\u20132 weeks. We will prepare your samples as quickly as possible.\"}}]}<\/script>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-03f1668 e-con-boxed e-flex e-con e-parent\" data-id=\"03f1668\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9afc346 elementor-widget elementor-widget-heading\" data-id=\"9afc346\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Aerogel Pipe Insulation in Practice<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-777a7ea elementor-widget elementor-widget-text-editor\" data-id=\"777a7ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>For aerogel pipe insulation, a multi-layer wrap typically matches the same duty at roughly one third the thickness of mineral systems, a large saving in space, support load and corrosion risk.<\/p><!--kw-2026-09-25-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c5836eb e-con-boxed e-flex e-con e-parent\" data-id=\"c5836eb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8fd3e9a elementor-widget elementor-widget-heading\" data-id=\"8fd3e9a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Installing Aerogel Pipeline Insulation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-977460a elementor-widget elementor-widget-text-editor\" data-id=\"977460a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Installing aerogel pipeline insulation follows the same wrap and jacket method as other blankets. The key is a continuous vapor barrier so the dry core stays dry across a 20-year service life.<\/p><!--kw-2026-09-25-->\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Kako aerogel izolacijske odeje zmanj\u0161ujejo toplotne izgube in kondenzacijo na industrijskih cevovodih. Tanj\u0161a izolacija, dalj\u0161a \u017eivljenjska doba. Oglejte si primere uporabe.<\/p>","protected":false},"author":1,"featured_media":533,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9],"tags":[],"class_list":["post-901","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Aerogel for Industrial Pipeline Insulation: One-Third the Thickness, Same Performance - Anchor Aerogel<\/title>\n<meta name=\"description\" content=\"Traditional industrial pipe insulation is thick, short-lived and moisture-prone. Aerogel blankets match the performance at ~1\/3 the thickness, up to ~650 \u00b0C, with a 20-year service life. \u2014 Anchor Technology Co., Ltd.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/anchor-aerogel.com\/sl\/anchor-tech-izolacija-cevovodov-iz-aerogela\/\" \/>\n<meta property=\"og:locale\" content=\"sl_SI\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Aerogel for Industrial Pipeline Insulation: One-Third the Thickness, Same Performance - Anchor Aerogel\" \/>\n<meta property=\"og:description\" content=\"Traditional industrial pipe insulation is thick, short-lived and moisture-prone. Aerogel blankets match the performance at ~1\/3 the thickness, up to ~650 \u00b0C, with a 20-year service life. \u2014 Anchor Technology Co., Ltd.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/anchor-aerogel.com\/sl\/anchor-tech-izolacija-cevovodov-iz-aerogela\/\" \/>\n<meta property=\"og:site_name\" content=\"Anchor Aerogel\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-01T03:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"469\" \/>\n\t<meta property=\"og:image:height\" content=\"295\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Anchor Tech Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Anchor Tech Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/anchor-tech-aerogel-pipeline-insulation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/anchor-tech-aerogel-pipeline-insulation\\\/\"},\"author\":{\"name\":\"Anchor Tech Team\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#\\\/schema\\\/person\\\/1fb2a61c6b00b9a4e340d577998a9daf\"},\"headline\":\"Aerogel for Industrial Pipeline Insulation: One-Third the Thickness, Same Performance\",\"datePublished\":\"2026-10-01T03:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/anchor-tech-aerogel-pipeline-insulation\\\/\"},\"wordCount\":401,\"publisher\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/anchor-tech-aerogel-pipeline-insulation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/009.webp\",\"articleSection\":[\"Application\"],\"inLanguage\":\"sl-SI\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/anchor-tech-aerogel-pipeline-insulation\\\/\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/anchor-tech-aerogel-pipeline-insulation\\\/\",\"name\":\"Aerogel for Industrial Pipeline Insulation: One-Third the Thickness, Same Performance - Anchor Aerogel\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/anchor-tech-aerogel-pipeline-insulation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/anchor-tech-aerogel-pipeline-insulation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/009.webp\",\"datePublished\":\"2026-10-01T03:00:00+00:00\",\"description\":\"Traditional industrial pipe insulation is thick, short-lived and moisture-prone. Aerogel blankets match the performance at ~1\\\/3 the thickness, up to ~650 \u00b0C, with a 20-year service life. \u2014 Anchor Technology Co., Ltd.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/anchor-tech-aerogel-pipeline-insulation\\\/#breadcrumb\"},\"inLanguage\":\"sl-SI\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/anchor-aerogel.com\\\/anchor-tech-aerogel-pipeline-insulation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sl-SI\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/anchor-tech-aerogel-pipeline-insulation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/009.webp\",\"contentUrl\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/009.webp\",\"width\":469,\"height\":295,\"caption\":\"About Aerogels, Here\u2019s What You Want to Know\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/anchor-tech-aerogel-pipeline-insulation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/anchor-aerogel.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Aerogel for Industrial Pipeline Insulation: One-Third the Thickness, Same Performance\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#website\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/\",\"name\":\"Anchor Aerogel\",\"description\":\"Advanced aerogel thermal insulation materials and blankets for extreme environments.\",\"publisher\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/anchor-aerogel.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sl-SI\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#organization\",\"name\":\"Anchor Aerogel\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sl-SI\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/wechat-image-logo.jpg\",\"contentUrl\":\"https:\\\/\\\/anchor-aerogel.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/wechat-image-logo.jpg\",\"width\":837,\"height\":405,\"caption\":\"Anchor Aerogel\"},\"image\":{\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/anchor-aerogel.com\\\/#\\\/schema\\\/person\\\/1fb2a61c6b00b9a4e340d577998a9daf\",\"name\":\"Anchor Tech Team\",\"sameAs\":[\"https:\\\/\\\/anchor-aerogel.com\"],\"url\":\"https:\\\/\\\/anchor-aerogel.com\\\/sl\\\/author\\\/164868441qq-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Aerogel za izolacijo industrijskih cevovodov: ena tretjina debeline, enaka u\u010dinkovitost - Anchor Aerogel","description":"Tradicionalna industrijska izolacija cevi je debela, kratkotrajna in dovzetna za vlago. Aerogel odeje dosegajo enako u\u010dinkovitost pri ~1\/3 debeline, do ~650 \u00b0C, z 20-letno \u017eivljenjsko dobo. \u2014 Anchor Technology Co., Ltd.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/anchor-aerogel.com\/sl\/anchor-tech-izolacija-cevovodov-iz-aerogela\/","og_locale":"sl_SI","og_type":"article","og_title":"Aerogel for Industrial Pipeline Insulation: One-Third the Thickness, Same Performance - Anchor Aerogel","og_description":"Traditional industrial pipe insulation is thick, short-lived and moisture-prone. Aerogel blankets match the performance at ~1\/3 the thickness, up to ~650 \u00b0C, with a 20-year service life. \u2014 Anchor Technology Co., Ltd.","og_url":"https:\/\/anchor-aerogel.com\/sl\/anchor-tech-izolacija-cevovodov-iz-aerogela\/","og_site_name":"Anchor Aerogel","article_published_time":"2026-10-01T03:00:00+00:00","og_image":[{"width":469,"height":295,"url":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009.webp","type":"image\/webp"}],"author":"Anchor Tech Team","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Anchor Tech Team","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/anchor-aerogel.com\/anchor-tech-aerogel-pipeline-insulation\/#article","isPartOf":{"@id":"https:\/\/anchor-aerogel.com\/anchor-tech-aerogel-pipeline-insulation\/"},"author":{"name":"Anchor Tech Team","@id":"https:\/\/anchor-aerogel.com\/#\/schema\/person\/1fb2a61c6b00b9a4e340d577998a9daf"},"headline":"Aerogel for Industrial Pipeline Insulation: One-Third the Thickness, Same Performance","datePublished":"2026-10-01T03:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/anchor-aerogel.com\/anchor-tech-aerogel-pipeline-insulation\/"},"wordCount":401,"publisher":{"@id":"https:\/\/anchor-aerogel.com\/#organization"},"image":{"@id":"https:\/\/anchor-aerogel.com\/anchor-tech-aerogel-pipeline-insulation\/#primaryimage"},"thumbnailUrl":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009.webp","articleSection":["Application"],"inLanguage":"sl-SI"},{"@type":"WebPage","@id":"https:\/\/anchor-aerogel.com\/anchor-tech-aerogel-pipeline-insulation\/","url":"https:\/\/anchor-aerogel.com\/anchor-tech-aerogel-pipeline-insulation\/","name":"Aerogel za izolacijo industrijskih cevovodov: ena tretjina debeline, enaka u\u010dinkovitost - Anchor Aerogel","isPartOf":{"@id":"https:\/\/anchor-aerogel.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/anchor-aerogel.com\/anchor-tech-aerogel-pipeline-insulation\/#primaryimage"},"image":{"@id":"https:\/\/anchor-aerogel.com\/anchor-tech-aerogel-pipeline-insulation\/#primaryimage"},"thumbnailUrl":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009.webp","datePublished":"2026-10-01T03:00:00+00:00","description":"Tradicionalna industrijska izolacija cevi je debela, kratkotrajna in dovzetna za vlago. Aerogel odeje dosegajo enako u\u010dinkovitost pri ~1\/3 debeline, do ~650 \u00b0C, z 20-letno \u017eivljenjsko dobo. \u2014 Anchor Technology Co., Ltd.","breadcrumb":{"@id":"https:\/\/anchor-aerogel.com\/anchor-tech-aerogel-pipeline-insulation\/#breadcrumb"},"inLanguage":"sl-SI","potentialAction":[{"@type":"ReadAction","target":["https:\/\/anchor-aerogel.com\/anchor-tech-aerogel-pipeline-insulation\/"]}]},{"@type":"ImageObject","inLanguage":"sl-SI","@id":"https:\/\/anchor-aerogel.com\/anchor-tech-aerogel-pipeline-insulation\/#primaryimage","url":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009.webp","contentUrl":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/11\/009.webp","width":469,"height":295,"caption":"About Aerogels, Here\u2019s What You Want to Know"},{"@type":"BreadcrumbList","@id":"https:\/\/anchor-aerogel.com\/anchor-tech-aerogel-pipeline-insulation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/anchor-aerogel.com\/"},{"@type":"ListItem","position":2,"name":"Aerogel for Industrial Pipeline Insulation: One-Third the Thickness, Same Performance"}]},{"@type":"WebSite","@id":"https:\/\/anchor-aerogel.com\/#website","url":"https:\/\/anchor-aerogel.com\/","name":"Anchor Aerogel","description":"Napredni aerogel toplotnoizolacijski materiali in odeje za ekstremna okolja.","publisher":{"@id":"https:\/\/anchor-aerogel.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/anchor-aerogel.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sl-SI"},{"@type":"Organization","@id":"https:\/\/anchor-aerogel.com\/#organization","name":"Anchor Aerogel","url":"https:\/\/anchor-aerogel.com\/","logo":{"@type":"ImageObject","inLanguage":"sl-SI","@id":"https:\/\/anchor-aerogel.com\/#\/schema\/logo\/image\/","url":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/07\/wechat-image-logo.jpg","contentUrl":"https:\/\/anchor-aerogel.com\/wp-content\/uploads\/2023\/07\/wechat-image-logo.jpg","width":837,"height":405,"caption":"Anchor Aerogel"},"image":{"@id":"https:\/\/anchor-aerogel.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/anchor-aerogel.com\/#\/schema\/person\/1fb2a61c6b00b9a4e340d577998a9daf","name":"Anchor Tech Team","sameAs":["https:\/\/anchor-aerogel.com"],"url":"https:\/\/anchor-aerogel.com\/sl\/author\/164868441qq-com\/"}]}},"_links":{"self":[{"href":"https:\/\/anchor-aerogel.com\/sl\/wp-json\/wp\/v2\/posts\/901","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/anchor-aerogel.com\/sl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/anchor-aerogel.com\/sl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/anchor-aerogel.com\/sl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/anchor-aerogel.com\/sl\/wp-json\/wp\/v2\/comments?post=901"}],"version-history":[{"count":1,"href":"https:\/\/anchor-aerogel.com\/sl\/wp-json\/wp\/v2\/posts\/901\/revisions"}],"predecessor-version":[{"id":4325,"href":"https:\/\/anchor-aerogel.com\/sl\/wp-json\/wp\/v2\/posts\/901\/revisions\/4325"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/anchor-aerogel.com\/sl\/wp-json\/wp\/v2\/media\/533"}],"wp:attachment":[{"href":"https:\/\/anchor-aerogel.com\/sl\/wp-json\/wp\/v2\/media?parent=901"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/anchor-aerogel.com\/sl\/wp-json\/wp\/v2\/categories?post=901"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/anchor-aerogel.com\/sl\/wp-json\/wp\/v2\/tags?post=901"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}